SARA-U2 series - Data Sheet
UBX-13005287 - R05 Early Production Information Electrical specifications
Page 22 of 51
4.2 Operating conditions
Unless otherwise indicated, all operating condition specifications are at an ambient temperature of 25°C.
Operation beyond the operating conditions is not recommended and extended exposure
beyond them may affect device reliability.
4.2.1 Operating temperature range
Symbol
Parameter
Min.
Typ.
Max.
Units
Remarks
Topr
Operating temperature range
-40
+85
°C
-20
+55
°C
Normal operating
temperature range
See section 4.2.1.1
-40
-20
°C
Extended operating
temperature range 1
See section 4.2.1.2
+55
+85
°C
Extended operating
temperature range 2
See section 4.2.1.3
Table 9: Environmental conditions
4.2.1.1 Normal operating temperature range
The cellular module is fully functional and meets the 3GPP specification across the specified temperature range.
4.2.1.2 Extended operating temperature range 1
The cellular module is fully functional across the specified temperature range. Occasional deviations from the
3GPP specification may occur.
4.2.1.3 Extended operating temperature range 2
The cellular module is functional across the specified temperature range. Occasional deviations from the 3GPP
specification may occur. Thermal protection including automatic shutdown is implemented for protection against
overheating. Thermal protection is disabled for emergency calls. For more details, see the u-blox AT Commands
Manual [4], +USTS AT command).